add pump control
parent
1bd732d812
commit
e6e0a01b6c
@ -0,0 +1,24 @@
|
||||
#include "avrIOhelper/io-helper.h"
|
||||
|
||||
#include "mqtt.h"
|
||||
extern Client mqtt_client;
|
||||
|
||||
void do_pumpe(){
|
||||
if(read_Input(BTN_BECKEN_FUELLEN, RISING)){
|
||||
set_Output(OUT_PUMPE_STARTSTOP, 1);
|
||||
set_Output(OUT_PUMPE_PWM, 1);
|
||||
set_Output(OUT_VENTIL_ABLASS, 0);
|
||||
set_Output(OUT_VENTIL_PUMPE, 0);
|
||||
set_Output(LED_PUMPE_AN, 1);
|
||||
send_value(&mqtt_client, "/Filamentanlage/02_Wasserbecken/state/pumpe_warm", 1);
|
||||
}
|
||||
|
||||
if(read_Input(BTN_BECKEN_LEEREN, RISING)){
|
||||
set_Output(OUT_PUMPE_STARTSTOP, 0);
|
||||
set_Output(OUT_PUMPE_PWM, 0);
|
||||
set_Output(OUT_VENTIL_ABLASS, 1);
|
||||
set_Output(OUT_VENTIL_PUMPE, 1);
|
||||
set_Output(LED_PUMPE_AN, 0);
|
||||
send_value(&mqtt_client, "/Filamentanlage/02_Wasserbecken/state/pumpe_warm", 0);
|
||||
}
|
||||
}
|
||||
Reference in New Issue